Biosensing

Ultra-low power electrochemical sensors

NNC_BMS003

The Nine Senses Series BMS003 is an ultra-low power, low-voltage programmable analog front-end sensing (AFE) chip available in 1.5V and 3V versions. The built-in low-noise amplifier effectively suppresses noise and interference to ensure the accuracy and reliability of bioelectric signal extraction. The chip also adopts a high-precision Δ-sigma oversampling AD converter with a maximum oversampling rate (OSR) of 2048. The chip can support three-electrode as well as four-electrode chemical sensors, and can realize accurate quantification of continuous blood glucose signals.

Ultra-low power consumption

Ultra-low power consumption

The innovative and freely configurable design allows the operating bias current and clock frequency of the chip to be determined by configuring the corresponding registers, thus realizing the optimal solution between performance and power consumption.

Wide range of applications

Wide range of applications

Capable of accurately capturing and resolving tiny biomolecular signals (e.g. glucose, lactic acid, uric acid, ketone bodies, cholesterol, creatinine, etc.) in body fluids such as sweat, saliva, urine, tissue fluids, etc., the chip is suitable for a wide range of medical monitoring scenarios such as continuous glucose monitoring (CGM).

Power-on self-calibration function

Power-on self-calibration function

Parameters such as bias voltage (error ≤±1mV) of electrochemical sensors can be automatically configured, while current detection is automatically calibrated.

Temperature compensation

Temperature compensation

Temperature compensation is included in the current acquisition, so there is almost no temperature drift in the temperature range of CGM application.

Product parameters

CategoryParametersDetail
Operating ParametersSupply Voltage1.5V / 3V
Package and Size

WLCSP (2.4mm × 2.48mm)

QFN (2.8mm × 2.8mm)

ADC Accuracy16bit

Acquisition Current Power Consumption

<15μA@1.5V

<12μA@3V

Oversampling rate range32-2048
Bias voltage range0.3-2V
Bias Voltage Accuracy10bit
Sensor Support ResolutionThree electrodes/four electrodes
Temperature Sensor Precision±0.5°C
Application

Dynamic glucose monitoring CGM 

Electrochemical Sensor

Sweat Sensor


Document download

Follow us

Get in touch

Nanochap Electronics Co., Ltd

Melbourne: Suite 3, Level 4, 10 Queens road, Melbourne, VIC 3004, Australia.

Phone: +61432800985


Ho Chi Minh city: Level 19, TTC Building, 253 Hoang Van Thu, Ward 2, Tan Binh District, Ho Chi Minh city, Vietnam.

Phone: +84967096581

Copyright © Nanochap Electronics Co.,Ltd. All Rights Reserved ICP registration number:No.: 2022101200005