Healthcare

Nanochap ENS001: Programmable Universal Stimulator Chip Leads the Way in Facial Palsy Stimulator Technology Innovation

Release time:2024-09-26

As an important branch of neurological rehabilitation, facial palsy treatment is undergoing unprecedented changes. Nanochap has revolutionized facial paralysis stimulation devices with its innovative ENS001 programmable universal stimulation chip.


The revolutionary application of the Nanochap ENS001 chip.

The introduction of the Nanochap ENS001 chip has revolutionized the face of facial palsy stimulation devices, bringing a completely new solution to the treatment of facial palsy:

  • Highly integrated and programmable: The ENS001 integrates an ARM Cortex-M0 MCU, a configurable boost DC converter, and a multi-channel highly flexible stimulation driver circuit. Through the dedicated programming interface, users can flexibly configure and adjust the operating parameters of the chip, such as stimulation waveform, frequency, pulse width, amplitude, etc., according to the specific treatment needs, realizing the fine control of electrical stimulation output.

  • Enhance precision and stability: ENS001 adopts constant current source technology, which can control the stimulation current more stably and ensure that the current waveform remains relatively stable after entering the human body. Compared to traditional constant voltage source technology, this greatly reduces the risk of damage to surrounding tissues.

  • Wide choice of stimulation waveforms: ENS001 supports a wide range of stimulation waveforms optimized for different types of facial paralysis based on extensive clinical research and practical experience.

  • Wide application potential: Thanks to the highly integrated and programmable nature of the ENS001, facial palsy stimulators equipped with the chip are not only suitable for facial palsy treatment, but can also be expanded to include neurological rehabilitation, pain management, and treatment of psychological disorders.


image.png


Limitations of Traditional Facial Palsy Stimulator

  1. Traditional facial palsy stimulators mainly rely on low-frequency pulsed current to stimulate facial muscles to promote local blood circulation and relieve muscle tension and spasm, thus achieving certain therapeutic purposes. However, such devices tend to have several significant limitations:

  2. Fixed parameters and lack of flexibility: the stimulation parameters (e.g. waveform, frequency, pulse width, etc.) of traditional facial palsy stimulators are usually preset and non-adjustable, making it difficult to meet the individualized treatment needs of different patients.

  3. Limited precision: Due to technical limitations, traditional devices may not be precise enough in current control, waveform generation, etc., which may affect the therapeutic effect.

  4. Limited scope of application: Traditional facial palsy stimulators are mainly used for mild facial palsy symptoms, and their efficacy is often limited in severe or complex cases.


image.png


Comparison Summary

Compared to traditional facial palsy stimulators, the Nanochap ENS001 chip offers significant improvements in the following areas:

  • Personalized treatment: Through programmability, flexible adjustment of treatment parameters is achieved to meet the individual needs of different patients.

  • Precision and Stability: The adoption of constant current source technology improves the precision and stability of current control and reduces the risk of treatment.

  • Abundant waveform choices: Supports a variety of optimized design of stimulation waveforms for precise treatment of different types of facial paralysis symptoms.

  • Wide application potential: not only limited to facial paralysis treatment, but also can be expanded to a number of medical fields, bringing benefits to more patients.


The application of Nanochap ENS001 chip in facial paralysis stimulator is a major breakthrough and innovative upgrade of the traditional technology. It not only improves the therapeutic effect and safety, but also expands the application scope of facial paralysis treatment, injecting new vitality into the development of neurological rehabilitation field.


Nanochap Stim Engines Series Programmable Universal Stimulation Chip ENS001 Advantages and Features

- Highly integrated to shorten product development cycle and simplify customer material management.

- Charge balancing technology, keeping the positive and negative half-cycle charges close to balance through charge replication technology.

- Small size, more suitable for portable products.

- Strong expandability, support multiple channels in parallel to realize multi-mode stimulation.

- Integration of current source controller and MCU to make a dedicated stimulation SoC.

- Freedom to edit the waveform, all 3 types of drivers can generate any current waveform.


Product Parameters 

- Operating voltage: 3V - 5V

- Operating Temperature: - 40°C - 85°C

- Low Power Mode: Sleep mode; Stop mode; Standby mode

- ARM core: 32-bit ARM Cortex-M0 CPU with up to 32 MHz frequency

- 4,8,23 channel stimulus drivers:

4-channel high current range driver (8 electrodes) (up to 60 V)

8-channel medium current range driver (16 electrodes) (60V max)

23-channel low current range driver (24 electrodes) (60V max.)

- Digital interface: UART*2, I2C*2, SPI*2

Related Products

Follow us

Get in touch

Nanochap Electronics Co., Ltd

Melbourne: Suite 3, Level 4, 10 Queens road, Melbourne, VIC 3004, Australia.

Phone: +61432800985


Ho Chi Minh city: Level 19, TTC Building, 253 Hoang Van Thu, Ward 2, Tan Binh District, Ho Chi Minh city, Vietnam.

Phone: +84967096581

Copyright © Nanochap Electronics Co.,Ltd. All Rights Reserved ICP registration number:No.: 2022101200005